WOBATECH

Wobatech AG | www.wobatech.com 161 WTA-X3.06-001 H10.003 TECHNICAL DATA H10 Tech. data Technical data Metrology Width b in mm Flatness tolerance v Dim. range at length l in mm from to to 1‘000 > 1‘000 to 2‘000 > 2‘000 to 3‘000 > 3‘000 to 4‘000 > 4‘000 to 5‘000 > 5‘000 to 6‘000 - 25 1.0 1.5 1.5 2.0 2.0 2.0 25 50 1.0 1.2 1.5 1.8 2.0 2.0 50 75 1.0 1.2 1.2 1.5 2.0 2.0 75 100 1.0 1.2 1.5 2.0 2.2 2.5 100 125 1.0 1.5 1.8 2.2 2.5 3.0 125 150 1.2 1.5 2.2 2.6 3.0 3.5 150 200 1.5 1.8 2.2 2.6 3.0 3.5 200 300 1.8 2.5 3.0 3.5 4.0 4.5 Straightness tolerance of the edge in longitudinal direction Straightness tolerance Length l1 in mm Tolerance H1 in mm from to - 1‘000 0.7 1‘000 2‘000 1.3 2‘000 3‘000 1.8 3‘000 4‘000 2.2 4‘000 5‘000 2.6 5‘000 6‘000 3.0 At a certain length I1 the given tolerance h1 is not to be exceeded. For each incremental length of I2 = 300 mm the deviation h2 is not to exceed 0.3 mm. Flatness tolerance (Twist tolerance) Parallelism tolerance Width b in mm max. size tolerance w in mm from to - 30 0.3 30 50 0.4 50 80 0.5 80 100 0.6 100 120 0.7 120 140 0.8 140 160 0.9 160 180 1.0 180 200 1.2 200 240 1.5 Parallelism tolerance (Angular tolerance) The parallelism tolerance w (angular tolerance) refers to unequal sides to the shorter side of the angle, i.e. it is measured from the longer side.